Charge System

Item

Servicing data

Input power

110 - 240 V AC

Rated frequency

60 Hz

Maximum rated electrical current

In normal charge

32A AC

Maximum power consumption

7.2 kVA (normal charge)

EV charge mode/Connection type

Normal charge: Mode 2, Mode 3/TYPE1

Installation requirements (information on protection against short-circuit current and equipment protection)

Applicable laws and regulations, and standards must be followed for protection measures against over-current and over-voltage. Always make sure to install appropriate over-current protection devices to the wiring of houses and buildings.

IP level

IP44: When charge connector is connected to charge inlet

IP67: Charging Cable

Operating temperature

On Board Charger

Ambient temperature: -30 ℃ (-22 ℉) to 85 ℃ (185 ℉)

Coolant temperature: -30 ℃ (-22 ℉) to 70 ℃ (158 ℉)

Charging Cable

Ambient temperature: -30 ℃ (-22 ℉) to 55 ℃ (131 ℉)

Storage temperature

On Board Charger

Ambient temperature: -40 ℃ (-40 ℉) to 85 ℃ (185 ℉)

Coolant temperature: -40 ℃ (-40 ℉) to 85 ℃ (185 ℉)

Charging Cable

Ambient temperature: -40 ℃ (-40 ℉) to 80 ℃ (176 ℉)

Applicable standards

On Board Charger

EN/IEC 61851-1, EN/IEC 61851-21, EN/IEC 61851-23, UL 2202

Charging Cable

NFPA 70, NFPA 79, SAE-J 1772, UL 62, UL 817, UL 2231-1, UL 2231-2, UL 2251, UL 2594, CSA C22.2 No. 280-16

Adapters

Do not use an adapter with the plug and connector of the charging cable. Do not use an extension cable.

Page top