Specifications

Charge System

Item

Servicing data

Input power

110 - 240 V AC

Rated frequency

60 Hz

Maximum rated electrical current

32 A (normal charge)

Maximum power consumption

7.2 kVA (normal charge)

Maximum charging current

150 A (quick charge)

Electrical leakage detection current for control box including genuine charge cable

5 mA

EV charge mode/Connection type

Normal charge: AC Level 1, AC level 2

Quick charge: CCS1 (Combo1)

Connection Type : TYPE1

Installation requirements

(information on protection against short-circuit current and equipment protection)

Applicable laws and regulations, and standards must be followed for protection measures against over-current and over-voltage.

Always make sure to install appropriate over-current protection devices to the wiring of houses and buildings.

IP level

IP44: When charge connector is connected to charge inlet

IP67: EV Supply Equipment(Charging Cable)

Operating temperature

Onboard charger: -30 °C (-22 °F) ― 85 °C (185 °F) (ambient temperature), -30 °C (-22 °F) ― 65 °C (149 °F) (coolant temperature)

EV Supply Equipment(Charging Cable) : -30 °C (-22 °F) ― 55 °C (131 °F) (ambient temperature)

Storage temperature

Onboard charger: -40 °C (-40 °F) ― 85 °C (185 °F) (coolant temperature), -40 °C (-40 °F) ― 85 °C (185 °F) (ambient temperature)

EV Supply Equipment(Charging Cable) : -40 °C (-40 °F) ― 80°C (176 °F) (ambient temperature)

Applicable standards

Onboard charger: EN/IEC 61851-1, EN/IEC 61851-21, EN/IEC 61851-23, UL 2202

EV Supply Equipment(Charging Cable) : NFPA 70, NFPA 79, SAE-J 1772, UL 62, UL 817, UL 2231-1, UL 2231-2, UL 2251, UL 2594, CSA C22.2 No.280-16

Adapters

Do not use an adapter on the charge plug and the charge connector.

Do not use an extension cable.

Page top