How to set up the charging
Select Settings from the home screen on Mazda Connect.
Select EV Settings from the setting screen.
Select the setting item you want to change from the displayed content.
Charge When Connected
Cancels charging schedule to allow immediate charging.
|
Available setting changes |
|---|
|
Enable, Disable |
The charging timer can also be canceled on the screen displayed on the center display when the power switch is switched OFF.
When the charging is completed using the Charge When Connected setting, the charging timer schedule is restored.
Charging Schedule
Selects desired vehicle charging days and times.
|
Function |
Available setting changes |
|
|---|---|---|
|
1 ---- |
Enable, Disable*1 |
Edit, Delete*2 |
|
2 ---- |
||
|
3 ---- |
||
|
4 ---- |
||
|
5 ---- |
||
|
6 ---- |
||
|
7 ---- |
||
If a list selected using the cursor has been set, the item can be Enable or Disable.
Settings can be Edit/Delete by sliding a list selected using the cursor to the right.
The charging timer does not work immediately after the lead-acid battery is removed or installed, or when no GPS signal has been received. When charging without receiving GPS, quick charging begins. When GPS signals are received, the charging timer becomes operational.
Immediately after switching to daylight savings, charging may occur at the charging timer time set before the switch to daylight savings until the power switch is switched ON.
Edit
|
Function |
Available setting changes |
|---|---|
|
Start Time Select the desired charging start time. |
Time (10-minute intervals) |
|
End Time Select the desired charging end time. |
Time (10-minute intervals) |
|
Repeat Select the day(s) of the week to repeat. |
Monday ― Sunday |
|
Charge Limit Select the desired charge limit method. |
According to Battery Charge Level, According to Estimated Range |
|
Battery Charge Level*1 Select the desired maximum charge level. |
100% ― 10% (10 levels) |
|
Estimated Range*2 Select the desired estimated range. |
In 10 km increments |
Can be changed when According to Battery Charge Level is selected for Charge Limit.
Use when you want to charge only the amount of charging you need. This helps you save power and prevent high voltage battery deterioration.
Can be changed when According to Estimated Range is selected for Charge Limit.
Use when you want to charge according to your planned driving distance.
The distance-to-full discharge changes depending on the driving conditions and surrounding environment. Check the actual remaining distance-to-full discharge.
If you change the distance unit after setting the Estimated Range, the Estimated Range will be calculated in the unit after the change. (If you change the units to miles after setting the estimated range to 100 km, the charge distance will be for 60 miles.)
A charging day is set using Repeat
If 1 repeat day is set, charging is repeated every week on the set day of the week.
Depending on the set days of the week, the Repeat indication is displayed as Weekdays, Weekends, and Daily. Otherwise, it is displayed as Custom.
Setting example
|
Function |
Available setting changes |
|---|---|
|
Start Time |
21 : 00 |
|
End Time |
6 : 00 |
|
Repeat |
Friday |
|
Charge Limit |
According to Battery Charge Level |
|
Battery Charge Level |
80 % |
In this case, charging is done every week from Friday at 21 : 00 hours to Saturday at 6:00 hours. However, if the Battery Charge Level reaches 80%, the charging is stopped even if it is before the End Time.
No day is set using Repeat
If no Repeat day is designated, charging is done only 1 time at the set hours.
Setting example (if settings below are made at 13 : 00 hours)
|
Function |
Available setting changes |
|---|---|
|
Start Time |
12 : 00 |
|
End Time |
18 : 00 |
|
Repeat |
Once |
|
Charge Limit |
According to Estimated Range |
|
Estimated Range |
50 km |
In this case, when the charge connector is connected, charging starts immediately for charging to 18 : 00 hours on the same day.
However, if a charging amount allowing a 50 km trip is reached, the charging is stopped even if it is before the end time.
Setting example (if settings below are made at 13 : 00 hours)
|
Function |
Available setting changes |
|---|---|
|
Start Time |
1 : 00 |
|
End Time |
8 : 00 |
|
Repeat |
Once |
|
Charge Limit |
According to Battery Charge Level |
|
Battery Charge Level |
100 % |
In this case, charging is done from the next day at 1 : 00 hours to 8 : 00 hours. However, if the Battery Charge Level reaches 100% is reached, the charging is stopped even if it is before the End Time.
Charge Limit for AC Charging
Sets the charge limit when using an AC charger.
|
Available setting changes |
|---|
|
100% ― 10% (10 levels) |
For normal charge, set the maximum charge limit of the high voltage battery. Set the Battery Charge Level of the charging timer for each charging timer setting.
Charge Limit for DC Fast Charging
Sets the charge limit when using a DC Fast charger.
|
Available setting changes |
|---|
|
100% ― 10% (10 levels) |
Charge Connector Lock
Configures when the charge connector is locked.
|
Available setting changes |
|---|
|
Locked When Charging Unlocks connector when charging is complete or vehicle is unlocked. |
|
Locked When Connected Unlocks connector only when vehicle is unlocked. |
|
Off Charge connector remains unlocked at all times. |
High Voltage Battery Heater
Configures the high voltage battery heater operation.
|
Available setting changes |
|---|
|
Automatic, Off |

Page top